Dear SCO Customer, The enclosed the SCOhelp for Localization Support Supplement for Open Server 5.0.0, contains the following updates: 1) A patch to SCO help to send the uncompressed size of the help file. The scohelp pages are stored compressed. When the pages are delivered to the browser, the files are uncompressed, but the size reported to the browser is of the compressed file. Hence the browser only reads a subset of the entire HTML page. 2) A patch to SCO help to correctly use the cgi-bin/man script. The cgi-bin program "man" does not work with Netscape Navigator. This patch corrects a problem with the httpd accept types. NOTE: This supplement (patch id: rs.2.5.c) is intended only for SCO systems based on SCO Open Server 5.0.0. It requires the following patches to be pre-installed to successfully install the SCO Help Supplement. Release supplement 500d Network supplement netms or net100 SCO Open Server 5.0.2 and Internet FastStart 1.0 do not use this patch. INSTALLATION AND REMOVAL INSTRUCTIONS Installing patches on SCO OpenServer 5.0.0 usually consists of two phases: "Loading" and "Applying". The instructions that follow enable you to both install the patch from distribution media or media image, as well as configure the patch to be installed from a remote SCO OpenServer 5.0.0 system over a TCP/IP network. I. LOADING THE PATCH 1. Log in as root. 2. If you are installing this supplement from the SCO Internet Family CD media, skip this step and proceed to step 3. If you are installing this supplement from a media image, there is a file called VOL.000.000. Copy the file to the /tmp directory. # cp path_where_the_file_exists/VOL.000.000 /tmp 3. Execute the command: # scoadmin software or double click on the Software Manager icon on the desktop. 4. Pull down the "Software" menu and select "Patch Management-->Load Patch". 5. You will see the "Begin Load Patch" menu. Be sure the local machine name is selected and choose "Continue". 6. You will see the "Select Media" menu. a. If you are loading this supplement from SCO Internet Family CD disk media, select the appropriate CD disk drive and choose "Continue". You will shortly see the "Select Patch-Product To Load on ... " menu. Select the patch called: SCOhelp Supplement for Localization Support (version rs.2.5.c) Proceed to step 7. b. If you are loading the patch from a media image per step 2, pull down the "Media Device" menu and select "Media Images", then choose "Continue". You will then see the "Enter Image Directory" menu. Enter /tmp and choose "OK". You will see the "Load Patch Preference" menu. Proceed to step 7. 7. Choose "Full" to load the patch. 8. You will see the "Load Patch Progress" window. If the patch loads successfully, you will see a "Message" window which states "Load Patch complete". Choose "OK". You are then returned to the main Software Manager window. 9. To apply the patch now, continue with step 2 under section II, "Applying the Patch". To exit the Software Manager now, select "Exit" from the "Host" menu. II. APPLYING THE PATCH 1. Log in as root. Execute the command: # scoadmin software or double click on the Software Manager icon on the desktop. 2. If you are installing this supplement from CD disk media, skip this step and proceed to step 3. If you are installing this supplement from a media image, there is a file called VOL.000.000. Copy the file to the /tmp directory. # cp path_where_the_file_exists/VOL.000.000 /tmp 3. You will see the "Begin Apply Patch" menu. Be sure that the local machine name is selected and choose "Continue". 4. You will see the "Select Media" menu. The "Hard Disk" menu item should already be selected. Choose "Continue". 5. You will be presented with the "Select Patch-product to Apply" menu. Highlight the "SCOhelp Supplement for Localization Support (version rs.2.5.c)" patch and then choose "Full" to continue. 6. You will see the "Apply Patch Progress" window as the system applies the patch. If the patch applies successfully you will see a "Message" window which states "Apply Patch complete." Choose "OK". You are then returned to the main Software Manager window. 7. Exit the Software Manager by choosing "Exit" from the "Host" menu. 8. Log in as root on tty01, and shut down the system: # shutdown -g0 -y After shutting down and rebooting the machine, application of the patch is complete. III. NOTES ON NETWORK INSTALLATION To install the patch on other SCO OpenServer 5.0.0 machines over the network, first load the patch as in section I above on a designated installation server. Then create the user "swadmin" on the installation server. When running the Software Manager on the system where the patch will be installed, you will be prompted for the source location of the patch in the "Begin Load Patch" window. Be sure to choose "From Another Host" during this phase. You will need to provide the name of the installation server, as well as the password of the "swadmin" user on the installation server, to initiate the installation process. IV. PATCH REMOVAL NOTE: Patches must be rolled back in the reverse order in which they were installed on a per-component basis. 1. Log in as root. 2. Execute the command: # scoadmin software or double click on the Software Manager icon in the desktop. 3. Pull down the "Software" menu and select "Patch Management-->Rollback Patch". 4. You will see the "Begin Rollback Patch" menu, and be asked to select patched software to rollback. Select "Visual Tcl" and choose "Continue". 5. You will see the "Patch Selection" window. Make sure that the "SCOhelp Supplement WServer component" patch is selected, and choose "Continue". 6. You will see the "Confirm Selected Patches" window. Choose "Rollback" to confirm removal of the "SCOhelp Supplement WServer Component" patch. 7. You will see the "Rollback Progress" window, as the system performs the rollback of the patch. If the patch rollback is successful you will see a "Message" window stating "Rollback Patch Complete". Choose "OK" and you will be returned to the Software Manager's main menu. 8. Pull down the "Software" menu and select "Patch Management-->Rollback Patch". 9. You will see the "Begin Rollback Patch" menu, and be asked to select patched software to rollback. Select "Standard X Clients" and choose "Continue". 10. You will see the "Patch Selection" window. Make sure that the "SCOHelp Supplement BaseX component" patch is selected, and choose "Continue". 11. You will see the "Confirm Selected Patches" window. Choose "Rollback" to confirm removal of the "SCOHelp Supplement BaseX component" patch. 12. You will see the "Rollback Progress" window, as the system performs the rollback of the patch. If the patch rollback is successful you will see a "Message" window stating "Rollback Patch Complete". Choose "OK" and you will be returned to the Software Manager's main 13. Pull down the "Software" menu and select "Patch Management-->Rollback Patch". 14. You will see the "Begin Rollback Patch" menu, and be asked to select patched software to rollback. Select "SCO UNIX System V Operating System" and choose "Continue". 15. You will see the "Patch Selection" window. Make sure that the "SCOhelp Supplement Unix Component" patch is selected, and choose "Continue". 16. You will see the "Confirm Selected Patches" window. Choose "Rollback" to confirm removal of the "SCOHelp Supplement Unix Component" patch. 17. You will see the "Rollback Progress" window, as the system performs the rollback of the patch. If the patch rollback is successful you will see a "Message" window stating "Rollback Patch Complete". Choose "OK" and you will be returned to the Software Manager's main 18. Exit the Software Manager by choosing "Exit" from the "Host" menu. 19. Log in as root on tty01, and shut down the system: # shutdown -g0 -y After shutting down and rebooting the machine, rollback of the patch is complete. 20. To also unload the patch, making it no longer available to be applied, follow steps 1 through 19 in this section. However, in step 3, choose: "Patch Management-->Unload Patch" instead of: "Patch Management-->Rollback Patch" If you have questions regarding this supplement, or the product on which it is installed, please contact your software supplier. We appreciate your business. SCO Support Services